AGI seismic fixture clamps

Select the Correct SFC for Different Lighting Fixture Configurations

Specific combinations of the five SFC (Seismic Fixture Clamp) models are deployed to provide positive attachment of light fixtures installed in various configurations at the suspended ceiling system are shown below:

Config.   SFC Model Set
Qty
Remarks

Single 2' x 4' Lighting Fixture

Single 2' x 4' lighting fixture configuration SFC1

1

  • Required to provide positive attachment of the light fixture to the ceiling grid.
  • Two hanger wires are not required.

Single 2' x 4' Lighting Fixture attached to main runners

AGI AC184 SFC single 2' x 4' fixture configuration 2 SFC1

1

  • Required to provide positive attachment of the lighting fixture to the ceiling grid.  
  • Two hanger wires are not required.
SFC1CFS

1

  • Required to attach the lighting fixture to the main and cross runners.
  • SFC1CFS is used to re-inforce the main runner joint at the lighting fixture.  
  • Two hanger wires are not required.

Two 2' x 4' Lighting Fixtures side-by-side

AGI AC184 SFC single 2' x 4' fixture configuration 3 SFC1

1

  • Required to provide positive attachment of the lighting fixtures to the ceiling grid.  
  • Two hanger wires are not required.
SFC1S

1

  • Required to provide positive attachment at the corners of the two adjoining lighting fixtures to the ceiling grid.  
  • Two hanger wires are not required.

Two 2' x4' Lighting Fixtures end-to-end

AGI AC184 SFC single 2' x 4' fixture configuration 4 SFC1

1

  • Required to provide positive attachment of the lighting fixtures to the ceiling grid.  
  • Two hanger wires are not required.
SFC1E

1

  • Required to provide positive attachment at the corners of the two adjoining lighting fixtures to the ceiling grid.  
  • Two hanger wires are not required.

Single 2' x 2' Lighting Fixture

AGI AC184 SFC single 2' x 4' fixture configuration 5 SFC1

1

  • Required to provide positive attachment of the lighting fixtures to the ceiling grid.  
  • Two hanger wires are not required.
SFC1CF

1

  • Required to provide regidity at the corners of the unoccupied ceiling grid.  
  • Two hanger wires are not required.

 

 AGI SFC product family

The lighting fixture is suspended to the ceiling grid by Seismic Fixture Clamps (SFC) at all four corners to ensure that it is earthquake safe.

eXTReMe Tracker